PRONTO PANEL








                                         COMPLIANCE




                                     Regulations for Intertenancy Walls







                                   Separation between sole occupancy units for Class 1 construction
                                require the wall to achieve an FRL of 60/60/60, and to achieve acoustic
                                            performance at or exceeding Rw+Ctr 50.

                                 The Pronto Panel Low Rise Intertenancy Wall System has achieved all
                                relevant fire and acoustic performance requirement as outlined below.


               Fire                                           Acoustic
               FRL 60/60/60                                   Rw+Ctr 50
               The Pronto Low-Rise Intertenancy Wall system achieves   The Pronto Low-Rise Intertenancy Wall has been laboratory
               an FRL of 60/60/60 as tested by Exova Warringtonfire to   tested by Day Design acoustics (5518 - 1B Rev D) and
               AS1530.4 (reports 50911900.3 and 51504400.2A). These   variations to the tested systems have been assessed by
               reports state that the wall system achieves an FRL of   PKA (report PKA105BKW). All systems in this manual
               60/60/60 up to a maximum height of 8 meters.   have been deemed to meet and in most cases exceed, the
                                                              minimum acoustic requirement of Rw+Ctr 50 for this type
               Non-Combustible                                of construction.
               Pronto Panel has been tested by CSIRO against AS 1530.1
               and deemed non-combustible (report FNC 11644).  Discontinuous Construction
                                                              Aluminium brackets provided by Brickworks secure the
               8m Maximum Height                              Pronto Panel to the frame at the top and base of each panel,
               The Pronto Low-Rise Intertenancy Wall has been designed   ensuring the wall is discontinuous construction.
               and tested to achieve the requirements of the NCC for
               construction up to a maximum height of 8 metres from the   Cavity
               base of the wall.                              The Pronto Low-Rise Intertenancy Wall System cavity
                                                              can be as low as 10mm on each side of the Panel without
                                                              compromising discontinuous construction.



























               Disclaimer:
               Brickworks takes no responsibility for any Pronto Panel that is not installed in accordance with this manual.